Our line of PFL Diesel Generators with Standby Power 16.5 — 66 kVA based on FAWDE engine are renowned for their reliability and efficiency, making them a popular choice for various applications.
Customizable configurations: Generators can be tailored to specific requirements, including soundproof enclosures, tropical radiators, and containerized design.
- High Efficiency: Protect PFL generstors are designed for optimal fuel consumption, ensuring lower operational costs.
- Durability: Built with robust materials, these generators are capable of withstanding harsh environmental conditions
- Low Emissions: generators comply with stringent emission standards, contributing to a cleaner environment.
- Easy Maintenance: The design facilitates straightforward maintenance, reducing downtime and service costs.
- Industrial Use: Ideal for manufacturing plants, construction sites, and mining operations where reliable power is crucial.
- Commercial Use: Suitable for shopping malls, hospitals, and office buildings to ensure uninterrupted power supply.
- Residential Use: Provides backup power for homes during outages, ensuring comfort and safety.
Note: General configuration not to be used for installation. See general dimension drawings for detail.
Model | Constructure | Dim“A”mm | Dim“B”mm | Dim“C”mm | Dry Weight kg | Fuel Tank Capacity L |
PFL16.5-O | Open set | 1740 | 650 | 1195 | 480 | 95 |
PFL16.5-C | Silent set | 2017 | 955 | 1100 | 800 | 60 |
PFL22-O | Open set | 1740 | 650 | 1195 | 520 | 95 |
PFL22-C | Silent set | 2017 | 955 | 1100 | 850 | 60 |
PFL27.5-O | Open set | 1740 | 650 | 1195 | 550 | 95 |
PFL27.5-C | Silent set | 2017 | 955 | 1100 | 870 | 60 |
PFL33-O | Open set | 1830 | 700 | 1185 | 600 | 105 |
PFL33-C | Silent set | 2017 | 955 | 1100 | 900 | 60 |
PFL44-O | Open set | 1900 | 955 | 1287 | 900 | 200 |
PFL44-C | Silent set | 2297 | 1055 | 1250 | 1100 | 100 |
PFL55-O | Open set | 1900 | 955 | 1287 | 900 | 200 |
PFL55-C | Silent set | 2397 | 1055 | 1250 | 1200 | 100 |
PFL66-O | Open set | 2000 | 955 | 1287 | 930 | 210 |
PFL66-C | Silent set | 2517 | 1055 | 1250 | 1250 | 100 |
Control Module ∇
Digital Instrumentation
- Generating set voltage
- Mains voltage
- Generating set frequency
- Generating set current
- Battery voltage
- Power (kVA-kW-kVAr)
- Power factor Cos φ
- Hours-counter
- Engine speed r.p.m
- Fuel level (%)
General Characteristics ∇
Item | Data |
Standby Power (kVA) | 16.5 — 66 |
Standby Power (kW) | 13.2 — 52.8 |
Prime Power (kVA) | 15 — 60 |
Prime Power (kW) | 12 -48 |
Power Factor (Cos Phi) | 0.8 |
Diesel Engine | FAWDE |
Frequency (Hz) | 50 |
Rated Speed (rpm) | 1500 |
Phase | 3 |
Standard Voltage (V) | 400/230 |
Available Voltages (V) | 380/220 · 415/240 |
Power Definition ∇
Standby Power(ESP): The standby power rating is applicable for supply emergency power in variable load applications in accordance with ISO8528-1, overload is not allowed.
Prime Power(PRP): The prime power is available for an unlimited number of annual operating hours in variable load applications, in accordance with ISO8528-1.
General Engine Data | |
Engine brand | FAWDE |
Engine model | documantation |
Engine type | 4-stroke diesel |
Governor type | Electronic / ECU |
Injection type | Direct |
Aspiration type | Naturally Aspirated, Turbocharged and Aftercooled |
Number of cylinders and arrangement | 4-L |
Bore and stroke (mm*mm) | 85 x 95 — 102 x 118 |
Displacement (L) | 2.27 — 3.86 |
Cooling system | Water-cooled |
Lube oil consumption with full load |
0.5%-1% of fuel consumption
|
Compression Ratio | 16.6-17.5:1 |
Air Filter | Dry |
Fuel Consumption | |
Fuel Consumption @ 100% load ESP (L/H) | 5.3 — 13.1 |
Fuel Consumption @ 100% load PRP (L/H) | 4.9 — 12.1 |
Fuel Consumption @ 75% load PRP (L/H) | 3.7 — 9.1 |
Fuel Consumption @ 50% load PRP (L/H) | 2.7 — 6.5 |
Air System | |
Intake air flow (L/s) | / |
Cooling air flow (L/s) | / |
Exhaust System | |
Maximum exhaust temperature (°C) | 440 — 550 |
Exhaust gas flow (L/s) | 4.2 — 13.8 |
Maximum allowed back pressure (kPa) | 6.7 |
Starting System | |
Starting power(kW) | 3.5 — 4.5 |
Recommended battery (Ah) | 60 |
Number of Batteries | 1 — 2 |
Auxiliary voltage (Vdc) | 12 |
Oil System | |
Engine oil capacity (L) | 7.8 — 13 |
Cooling System | |
Total coolant capacity (L) | 4.85-18.8 |
Terms of use ∇
According to the standard, the nominal power assigned by the genset is given for 25 ℃ air inlet temperature, of a barometric pressure of 100 kPA (100m A.S.L) and 30%.
Alternator Data | |
Number of phase | 3 |
Power factor (Cos Phi) | 0.8 |
Poles | 4 |
Winding Connections (standard) | Star-serie |
Insulation | H class |
Enclosure(according IEC-34-5) | IP23 |
Excitation system | Self-excited, brushless |
Voltage regulator | AVR (Electronic) |
No. of bearings | Single bearing |
Coupling system | Flexible disc |
Coating type |
Standard (Vacuum impregnation)
|