PFL

Diesel Generators 16.5 - 66 kVA

Industrial generator sets ebased on FAWDE engines for any power generation application
Features
Specifications
Download

Our line of PFL Diesel Generators with Standby Power 16.5 — 66 kVA based on FAWDE engine are renowned for their reliability and efficiency, making them a popular choice for various applications.

Customizable configurations: Generators can be tailored to specific requirements, including soundproof enclosures, tropical radiators, and containerized design.

Key Advantages
  • High Efficiency: Protect PFL generstors are designed for optimal fuel consumption, ensuring lower operational costs.
  • Durability: Built with robust materials, these generators are capable of withstanding harsh environmental conditions
  • Low Emissions: generators comply with stringent emission standards, contributing to a cleaner environment.
  • Easy Maintenance: The design facilitates straightforward maintenance, reducing downtime and service costs.
Applications
  • Industrial Use: Ideal for manufacturing plants, construction sites, and mining operations where reliable power is crucial.
  • Commercial Use: Suitable for shopping malls, hospitals, and office buildings to ensure uninterrupted power supply.
  • Residential Use: Provides backup power for homes during outages, ensuring comfort and safety.
Dimensions , weights & Fuel Tank

Note: General configuration not to be used for installation. See general dimension drawings for detail.

Model Constructure Dim“A”mm Dim“B”mm Dim“C”mm Dry Weight kg Fuel Tank
Capacity L
PFL16.5-O Open set 1740 650 1195 480 95
PFL16.5-C Silent set 2017 955 1100 800 60
PFL22-O Open set 1740 650 1195 520 95
PFL22-C Silent set 2017 955 1100 850 60
PFL27.5-O Open set 1740 650 1195 550 95
PFL27.5-C Silent set 2017 955 1100 870 60
PFL33-O Open set 1830 700 1185 600 105
PFL33-C Silent set 2017 955 1100 900 60
PFL44-O Open set 1900 955 1287 900 200
PFL44-C Silent set 2297 1055 1250 1100 100
PFL55-O Open set 1900 955 1287 900 200
PFL55-C Silent set 2397 1055 1250 1200 100
PFL66-O Open set 2000 955 1287 930 210
PFL66-C Silent set 2517 1055 1250 1250 100

Control Module

Digital Instrumentation

  • Generating set voltage
  • Mains voltage
  • Generating set frequency
  • Generating set current
  • Battery voltage
  • Power (kVA-kW-kVAr)
  • Power factor Cos φ
  • Hours-counter
  • Engine speed r.p.m
  • Fuel level (%)

General Characteristics

Item Data
Standby Power (kVA) 16.5 — 66
Standby Power (kW) 13.2 — 52.8
Prime Power (kVA) 15 — 60
Prime Power (kW) 12 -48
Power Factor (Cos Phi) 0.8
Diesel Engine FAWDE
Frequency (Hz) 50
Rated Speed (rpm) 1500
Phase 3
Standard Voltage (V) 400/230
Available Voltages (V) 380/220 · 415/240

Power Definition

Standby Power(ESP): The standby power rating is applicable for supply emergency power in variable load applications in accordance with ISO8528-1, overload is not allowed.

Prime Power(PRP): The prime power is available for an unlimited number of annual operating hours in variable load applications, in accordance with ISO8528-1.

General Engine Data
Engine brand FAWDE
Engine model documantation
Engine type 4-stroke diesel
Governor type Electronic / ECU
Injection type Direct
Aspiration type Naturally Aspirated,
Turbocharged and Aftercooled
Number of cylinders and arrangement 4-L
Bore and stroke (mm*mm) 85 x 95 — 102 x 118
Displacement (L) 2.27 — 3.86
Cooling system Water-cooled
Lube oil consumption with full load
0.5%-1% of fuel consumption
Compression Ratio 16.6-17.5:1
Air Filter Dry
Fuel Consumption
Fuel Consumption @ 100% load ESP (L/H) 5.3 — 13.1
Fuel Consumption @ 100% load PRP (L/H) 4.9 — 12.1
Fuel Consumption @ 75% load PRP (L/H) 3.7 — 9.1
Fuel Consumption @ 50% load PRP (L/H) 2.7 — 6.5
Air System
Intake air flow (L/s) /
Cooling air flow (L/s) /
Exhaust System
Maximum exhaust temperature (°C) 440 — 550
Exhaust gas flow (L/s) 4.2 — 13.8
Maximum allowed back pressure (kPa) 6.7
Starting System
Starting power(kW) 3.5 — 4.5
Recommended battery (Ah) 60
Number of Batteries 1 — 2
Auxiliary voltage (Vdc) 12
Oil System
Engine oil capacity (L) 7.8 — 13
Cooling System
Total coolant capacity (L) 4.85-18.8

Terms of use

According to the standard, the nominal power assigned by the genset is given for 25 ℃ air inlet temperature, of a barometric pressure of 100 kPA (100m A.S.L) and 30%.

Alternator Data
Number of phase 3
Power factor (Cos Phi) 0.8
Poles 4
Winding Connections (standard) Star-serie
Insulation H class
Enclosure(according IEC-34-5) IP23
Excitation system Self-excited, brushless
Voltage regulator AVR (Electronic)
No. of bearings Single bearing
Coupling system Flexible disc
Coating type
Standard (Vacuum impregnation)
Datasheet
File Name Language File Download
Union datasheets PFL generators 16.6 - 66 kVA ENG Download
PFL-16,5 ENG Download
PFL-22 ENG Download
PFL-27,5 ENG Download
PFL-33 ENG Download
PFL-44 ENG Download
PFL-55 ENG Download
PFL-66 ENG Download