PML

Diesel Generators 715 - 2750 kVA

Powered by Mitsubishi three-phase engine сan be found in a multitude of applications
Features
Specifications
Download

PML Diesel Generator sets with Standby Power 715 — 2750 kVA can be found in a multitude of applications including standby, emergency power, prime power for peak shaving or baseload power plants

Mitsubishi Japan diesel engines featuring with low fuel consumption, long service intervals and low emissions.

Key Advantages
  • High-Quality Manufacturing: Designed and manufactured in France. Complies with ISO 9001:2018 quality standards. Meets European health, safety, and environmental protection standards (CE certification).
  • Modular Design: Offers a wide variety of configurations and options. Adaptable to meet any technical specification. Reduces on-site adaptation and commissioning time.
  • Compact and Space-Efficient: Fits into any standard ISO container. Occupies minimal space in power houses.
  • Robust and Reliable Performance: Suitable for diverse applications, including emergency standby and continuous 24/7 use. Handles variable loads for unlimited durations.
  • Easy maintenance and operation (mechanical injection, open control system, integrated auxiliary systems)
Versatile Applications
  • Ideal for hospitals
  • Data centers
  • Commercial or municipal buildings
  • Industries
  • Decentralized power plants
Dimensions , weights & Fuel Tank

Note: General configuration not to be used for installation. See general dimension drawings for detail.

Model Constructure Dim“A”mm Dim“B”mm Dim“C”mm Dry Weight kg Fuel Tank
Capacity L
PML715-C Open set 3570 1495 2230 5700 800
PML715-C Silent set 5000 1600 2545 7000 800
PML825-O Open set 4000 1690 2250 6380 1000
PML825-C Silent set 5682 1950 2545 8100 1000
PML1400-O Open set 4350 2200 2250 / /
PML1400-P 20ft container 6058 2438 2591 / /
PML1540-O Open set 4375 2200 2465 / /
PML1540-P 20ft High container 6058 2438 2896 / /
PML1650-O Open set 4830 2200 2520 / /
PML1650-P 20ft High container 6058 2438 2896 / /
PML1760-P Container Set 12192 2438 2896 18000 REQ
PML1915-O Open set 4830 2200 2520 / /
PML1915-P 40ft High container 12192 2438 2896 / /
PML2100-O Open set 5475 2170 2930 / /
PML2100-P 40ft High container 12192 2438 2896 / /
PML2200-O Open set 5660 2200 2882 / /
PML2200-P 40ft High container 12192 2438 2896 / /
PML2500-O Open set 6005 2200 3000 / /
PML2500-P 40ft High container 12192 2438 2896 / /
PML2750-O Open set 6790 2200 2500 RECQ RECQ
PML2750-C Silent set 12192 2438 2896 RECQ RECQ

Control Module

Digital Instrumentation

  • Generating set voltage
  • Mains voltage
  • Generating set frequency
  • Generating set current
  • Battery voltage
  • Power (kVA-kW-kVAr)
  • Power factor Cos φ
  • Hours-counter
  • Engine speed r.p.m
  • Fuel level (%)

General Characteristics

Item Data
Standby Power (kVA) 715 — 2750
Standby Power (kW) 572 — 2200
Prime Power (kVA) 650 — 2500
Prime Power (kW) 520 — 2000
Power Factor (Cos Phi) 0.8
Diesel Engine Mitsubishi
Frequency (Hz) 50
Rated Speed (rpm) 1500
Phase 3
Standard Voltage (V) 400/230
Available Voltages (V) 380/220 · 415/240

Power Definition

Standby Power(ESP): The standby power rating is applicable for supply emergency power in variable load applications in accordance with ISO8528-1, overload is not allowed.

Prime Power(PRP): The prime power is available for an unlimited number of annual operating hours in variable load applications, in accordance with ISO8528-1.

General Engine Data
Engine brand Mitsubishi
Engine model Documentation
Engine type 4-stroke diesel
Governor type ECU
Injection type Direct
Aspiration type Turbocharged and water-air intercooler
Number of cylinders and arrangement 6-L -16-V
Bore and stroke (mm*mm) 170 x 220
Displacement (L) 29.96 — 79,9
Cooling system Water-cooled
Lube oil consumption with full load 0.4 g/kw.h
Compression Ratio 14:1 — 14.4:1
Air Filter Dry
Fuel Consumption
Fuel Consumption @ 100% load ESP (L/H) NA
Fuel Consumption @ 100% load PRP (L/H) 139 — 464
Fuel Consumption @ 75% load PRP (L/H) NA
Fuel Consumption @ 50% load PRP (L/H) NA
Air System
Intake air flow (L/s) 50 — 191
Cooling air flow (L/s) 720 — 1650
Exhaust System
Maximum exhaust temperature (°C) 500 — 550
Exhaust gas flow (L/s) 132 — 506
Maximum allowed back pressure (kPa)
Starting System
Starting power(kW) 7.5 — 15
Recommended battery (Ah) 120
Number of Batteries 2 — 4
Auxiliary voltage (Vdc) 24
Oil System
Engine oil capacity (L) 94 — 290
Cooling System
Total coolant capacity (L)

Terms of use

According to the standard, the nominal power assigned by the genset is given for 25 ℃ air inlet temperature, of a barometric pressure of 100 kPA (100m A.S.L) and 30%.

Alternator Data
Number of phase 3
Power factor (Cos Phi) 0.8
Poles 4
Winding Connections (standard) Star-serie
Insulation H class
Enclosure(according IEC-34-5) IP23
Excitation system Self-excited, brushless
Voltage regulator AVR (Electronic)
No. of bearings Single bearing
Coupling system Flexible disc
Coating type
Standard (Vacuum impregnation)
Datasheet
File Name Language File Download
Union datasheets PML generators 770 - 2750 kVA ENG Download
PML-715 ENG Download
PML-825 ENG Download
PML-1400 ENG Download
PML-1540 ENG Download
PML-1650 ENG Download
PML-1760 ENG Download
PML-1915 ENG Download
PML-2100 ENG Download
PML-2200 ENG Download
PML-2500 ENG Download
PML-2750 ENG Download