PML

Diesel Generators 880 - 3250 kVA

Industrial range Powered by MTU three-phase engine, soundproof, operating in automatic, manual, signal or test mode
Features
Specifications
Download

PML Diesel Generators with Standby Power 880 — 3250 kVA are vastly used in transportation sector, buildings, telecom, schools, hospitals, ships, oil fields and industrial power supplying area etc, which can be applied as main power or backup generator/standby generator/emergency generator.

MTU diesel engines featuring with low fuel consumption, long service intervals and low emissions.

Main Characteristics Of Generators
  • Reasonable structure design, modular structure design and convenience in maintenance
  • Strong adaptability of engine, no need of power correctio at the altitude of 400 m when the environment temperature reaches 40 ° C; excellent engine load response
  • Extremely excellent fuel economy, low fuel consumption and oil consumption, and the indicators can reach 190 ~ 200 g/Kwh, with a low operating cost
  • Excellent exhaust emissions targets, NOx value <2000mg /m;Low particle emissions, to meet all emission standards
  • A long interval of overhaul, up to 24000 hours.(note:general domestic units for 8,000 hours, Japanese American units for 12,000 hours)
  • Intervals of oil change for high quality oil is up to 1000 hours, being able to run 24 hours
  • No smoke phenomenon during the start-up;low noise, low vibration;good indexes in volume-to-power and weight-to-power
  • Electronic management system with the function of self-diagnosis
Dimensions , weights & Fuel Tank

Note: General configuration not to be used for installation. See general dimension drawings for detail.

Model Constructure Dim“A”mm Dim“B”mm Dim“C”mm Dry Weight kg Fuel Tank
Capacity L
PML880-5 Open set 4300 2050 2200 REQ
PML880-5S Silent set 6080 2438 2591 REQ
PML1000-5 Open set 4300 1900 2200 REQ
PML1000-5S Silent set 6080 2438 2591 REQ
PML1100-5 Open set 4350 1900 2200 REQ
PML1100-5S Silent set 6080 2438 2591 REQ
PML1250-5 Open set 4460 1900 2325 REQ
PML1250-5S Silent set 6080 2438 2591 REQ
PML1375-5 Open set 5000 2060 2200 REQ
PML1375-5S Silent set 6080 2438 2896 REQ
PML1500-5 Open set 5000 2270 2450 REQ
PML1500-5S Silent set 12192 2438 2896 REQ
PML1800-5 Open set 5650 2200 2565 REQ
PML1800-5S Silent set 12192 2438 2896 REQ
PML2000-5C Open set 5650 2200 2565 REQ
PML2000-5CS Silent set 12192 2438 2896 REQ
PML2200-5 Open set 5650 2200 2565 REQ
PML2200-5S Silent set 12192 2438 2896 REQ
PML2500-5 Open set 6000 2575 2560 REQ
PML2500-5S Silent set 12192 2438 2896 REQ
PML2750-5 Open set 6500 2600 2560 REQ
PML2750-5S Silent set 12192 2438 2896 REQ
PML3000-5C Open set 6500 2600 2560 REQ
PML3000-5C S Silent set 12192 2438 2896 REQ
PML3250-5 Open set 6500 2600 2560 REQ
M3250-5 Silent set 12192 2438 2896 REQ

Control Module

Digital Instrumentation

  • Generating set voltage
  • Mains voltage
  • Generating set frequency
  • Generating set current
  • Battery voltage
  • Power (kVA-kW-kVAr)
  • Power factor Cos φ
  • Hours-counter
  • Engine speed r.p.m
  • Fuel level (%)

General Characteristics

Item Data
Standby Power (kVA) 880 — 3250
Standby Power (kW) 704 — 2600
Prime Power (kVA) 800 — 3000
Prime Power (kW) 600 -2400
Power Factor (Cos Phi) 0.8
Diesel Engine MTU
Frequency (Hz) 50
Rated Speed (rpm) 1500
Phase 3
Standard Voltage (V) 400/230
Available Voltages (V) 380/220 · 415/240

Power Definition

Standby Power(ESP): The standby power rating is applicable for supply emergency power in variable load applications in accordance with ISO8528-1, overload is not allowed.

Prime Power(PRP): The prime power is available for an unlimited number of annual operating hours in variable load applications, in accordance with ISO8528-1.

General Engine Data
Engine brand MTU
Engine model 12V-20V
Engine type 4-stroke diesel
Governor type ECU
Injection type Direct
Aspiration type Turbocharger and intercooler
Number of cylinders and arrangement 12-20V
Bore and stroke (mm*mm) 130 x 150 — 170 x 210
Displacement (L) 22.88 — 95,4
Cooling system Water-cooled
Lube oil consumption with full load
0.5%-1% of fuel consumption
Compression Ratio 16:1 — 16.4:1
Air Filter Dry
Fuel Consumption
Fuel Consumption @ 100% load ESP (L/H)
Fuel Consumption @ 100% load PRP (L/H) 170.2 — 557.6
Fuel Consumption @ 75% load PRP (L/H) 124.2 — 409.6
Fuel Consumption @ 50% load PRP (L/H) 83.5 — 283.1
Air System
Intake air flow (L/s)
Cooling air flow (L/s) — 3,3
Exhaust System
Maximum exhaust temperature (°C) 565 — 510
Exhaust gas flow (L/s) 2500 — 8800
Maximum allowed back pressure (kPa) 8,5
Starting System
Starting power(kW) 9
Recommended battery (Ah) 120
Number of Batteries 2 — 4
Auxiliary voltage (Vdc) 24
Oil System
Engine oil capacity (L) 77 — 390
Cooling System
Total coolant capacity (L) 90 — 255

Terms of use

According to the standard, the nominal power assigned by the genset is given for 25 ℃ air inlet temperature, of a barometric pressure of 100 kPA (100m A.S.L) and 30%.

Alternator Data
Number of phase 3
Power factor (Cos Phi) 0.8
Poles 4
Winding Connections (standard) Star-serie
Insulation H class
Enclosure(according IEC-34-5) IP23
Excitation system Self-excited, brushless
Voltage regulator AVR (Electronic)
No. of bearings Single bearing
Coupling system Flexible disc
Coating type
Standard (Vacuum impregnation)
Datasheet
File Name Language File Download
Union datasheets PML generators 880 - 3250 kVA ENG Download
PML-880-datasheet.pdf ENG Download
PML-1000-datasheet.pdf ENG Download
PML-1100-datasheet.pdf ENG Download
PML-1250-datasheet.pdf ENG Download
PML-1375-datasheet.pdf ENG Download
PML-1500-datasheet.pdf ENG Download
PML-1800-datasheet.pdf ENG Download
PML-2000-datasheet.pdf ENG Download
PML-2200-datasheet.pdf ENG Download
PML-2500-datasheet.pdf ENG Download
PML-2750-datasheet.pdf ENG Download
PML-3000-datasheet.pdf ENG Download
PML-3250-datasheet.pdf ENG Download