The Protect iSmart L series single row cabinet data center integrates all needed equipment into cabinet with closed hot and cold aisle, kinds of sensors monitored and managed by power and environment system, which standardize the whole data center to smaller space, comes with remote intelligent controlling, provides safe and reliable operation environment. No need for professional engineer maintenance which simplify construction, operating and maintenance.
Structure and Composition ∇
Applicable Scene ∇
Computer rooms of medium and small enterprises, government branch offices, commercial, medical, education, power, communication and other scenes.
Floor area and System Capacity ∇
- The overall area of a single cabinet is 0.9㎡,which is suitable for computer rooms within 20-60㎡.
- Capacity of single cabinet≈3~7kVA
- All components follow domestic and international standardized production standards to ensure product quality
- Pre-installation, pre-commissioning and other process are controlled at various levels to ensure product installation and operation safe and reliable
- Controlled at various levels to ensure product installation and operation safe and reliable
- Integrated design, improve overall system reliability
- Intelligent pop-up door system ensure the continuous operation of the system effectively
- Redundant design, integrated intelligent monitoring system, ensure the safe and reliable operation of the computer room
- Array/rack mount refrigeration, precise cooling, greatly improve cooling efficiency, compared with traditional computer room energy saving 25%
- The system adapt N+X online high-efficiency modular UPS, equipped with intelligent sleep function making system save more energy
- Remote operation and maintenance, human-free design, saving TCO
- Closed hot and cold channels, cooling effectively, realize air inner circulation to reduce operating costs
- Engineering free design, suitable for various scenes, install rapidly
- Modular design of power distribution, hot-swappable ,easy installation and maintenance
- The system does not need special decoration treatment, the equipment is ready to use. Installation and commissioning cycle only need 4-6 hours
- • A single cabinet is a complete system, which can be easily and quickly expanded to 16 cabinets side by side
- Intelligently monitor power supply and environment status
- Instant and real-time alarm through various ways(SMS, sound and light, e-mail,phone)
- The monitoring system is compatible with many parts(screen, remote APP, local LCD, remote WEB); friendly HMI
- The monitoring system is compatible with many parts(screen, remote APP, local LCD, remote WEB); friendly HMI
Airflow Reference Chart and Application Scenario ∇
Note: : The layout can be adjusted according to the equipment condition
Parameters ∇
iSmart L series single row data center (closed hot and cold aisles) |
|||
Overall plan | IT rated power | 2-15 cabinets | |
Mains | 220Vac, 50/60Hz, 1Ph+N+PE; 380Vac, 50/60Hz, 3Ph+N+PE |
||
Ambient temperature | 0-45℃ | ||
IP Class | IP5X | ||
Altitude |
1000m, derating for >1000m
|
||
Cabinet | Dimension (W*D*H) | 600*1400*2000mm(Without caster) | |
Door Security | Fingerprint+IC/ID card+Password | ||
Display | 10.1 inch touch screen LCD | ||
Lighting | Front and rear LED, front Tri-color LED | ||
Cable entry | Top and bottom | ||
Emergency Method | Pop-up door system | ||
Power Supply and Distribution System |
Distribution system | Total input current: | 63-200A |
Thunder protection: | C Level | ||
UPS | Capacity | 10kVA-90kVA | |
Input Voltage
|
220Vac, 50/60Hz, 1Ph+N+PE; 380Vac, 50/60Hz, 3Ph+N+PE |
||
Operation Mode
|
1(phase in)/1(phase out), 3/1, 3/3 | ||
Battery
|
Battery pack/cabinet
|
||
PDU | Normal |
2pcs, 16ports(13*C10A + 3*C16 )
|
|
Intelligent |
Intelligent PDU 24 ports (optional)
|
||
Monitoring System
|
Dynamic Environment Monitoring |
Intelligent intergrated monitoring host
|
|
Standard power collection | |||
Other Optional Accessories | SMS alarm(optional) | ||
Audible and visual alarm(optional)
|
|||
Environment Monitoring | Smoke sensor*1, can have an addition | ||
Temperature&humidity sensor(optional) | |||
Water leakage sensor*1 | |||
Webcam (optional) | |||
Infrared detector (optional) | |||
Infrared detector(optional) | |||
Refrigeration system | Power Supply | Mains power supply | |
Cooling Capacity | 3.7-25kW | ||
Installation Method | Rack-mount/array can be chosen | ||
Inlet Outlet Method |
Air flow out from ahead and circle to back
|
||
Compressor Type | Variable frequency |
Note: The above parameters are for reference only, the actual configuration parameters are based on customer needs.
The difference with traditional solutiont ∇
iSmart L series single row data center | iSmart L series single row data center | |
Design | Pre-commissioning in dustry, put into use directly | Different supplier coordinate |
Power Distribution | Rack mount, modular, including thunder protection |
Isolated design, installation without thunder protection
|
Installation | Distributed wiring, integrated in dustry, modular |
Long construction period, design on site, lack of reliability
|
Scalability | All components are modular, adjust module number rapidly | Lack of expandability |
Construction Time | 4-6 hours | 40 days(including decoration) |
Appearance | Unified and harmonious appearance | Hard to unified size/color |
Dustproof | Totally enclosed system, IP5X,targeted protection of core equipment | Not available(high cost of dustproof) |
Cooling efficiency | Enclosed hot and cold air channel, cooling by the nearest AC, improve cooling efficiency |
No isolation of hot and cold air channel, low utilization
|
Noise | <45dB(A) | >65dB, not suitable for human long-term work |
Monitoring System | Local and remote monitoring, human-free |
Isolated monitoring equipment, different interface,incompatible
|
Client interface | Embed Linux system, long-term operation safe and steady, graphical interface, easy management |
Industrial PC, easy to crashing, monitor interface incompatible
|
Emergency solution | Emergency pop-up door, make good use of room to dissipate heat, maximize the time of emergency operation | Not available |
Service | Unified brand and service, full service during the life of product |
Different guarantee period service interface and phone number
|